Outdoor Optical Cable

Outdoor Optical Cable

Uni-tube metal duct fiber cable GYXY
GYXY duct fiber cable, optical fibers are housed in a loose tube that is made of high-modulus plastic (PBT) and filled with tube filling compound. Two steel wires are placed in parallel outside the tube, and a round-shape PE sheath is extruded.
Send Inquiry

Description

Technical Parameters

our company

 

 

company
30+ years
Our factory was found in 1992, first start with coaxial cable which was one of the biggest manufacturers in lin'an city.In year of 2001 started focusing on the production of optical cables.
30+ countries
In year of 2008, set up international sales department and sale optical fiber cable to more than 30 countries and have 18 years` rich experience to export cables .

 

Features

 
  • Loose tube filling compound ensure a critical protection of fiber.
  • Two parallel steel wires ensure tensile strength.
  • PE sheath protects cable form ultraviolet radiation.
  • Small diameter, light weight and friendly installation.
  • Crush resistance and flexibility.

 

Environmental Characteristics

 


• Transport/storage temperature: -40℃ to +60℃

 

Delivery Length

 


• Standard reel length: 2km/drum or 3km/drum; other lengths are also available.

 

Standard order payment

 

 

  • Payment term: T/T, L/C, D/P...
  • For small orders: credit cards, Western Union money transfer and PayPal are all accepted.
  • For other complex payment methods, further discussion is possible.

 

own brand

 

 

FTTH drop cable-Ink printing
FTTH drop cable-Ink printing
Flat cable-Plasma pringting
Flat cable-Plasma pringting
Outdoor cable GYTC8S-Iron printing
Outdoor cable GYTC8S-Iron printing
Jumper cable- SC/UPC-SC/APC
Jumper cable- SC/UPC-SC/APC
GYTC8S 24 core -wooden drum
GYTC8S 24 core -wooden drum
FTTH cable-1km drum
FTTH cable-1km drum
FTTH cable-carton packing
FTTH cable-carton packing
Patch cords-Pallet package
Patch cords-Pallet package
 
 

 

Pack and ship

 
Patch cords in Pallet delivery
Patch cords in Pallet delivery
FTTH cable in cartons packing
FTTH cable in cartons packing
Flat cable in plywood drum package
Flat cable in plywood drum package
4b86f9a7e7a1b777db558f0849be4352
Composite drum full loaded into contianer
eedd5e3aac661809b4fc7f60d27f57d8
Solid wooden drum loading photo
 
 

 

Tips

# Complete Introduction to GYFXY Duct Optical Cable

 

## I. Meaning of Model Letters (National Standard YD/T 769)

**GYFXY = Central Tube Type Non-metallic Unarmored Outdoor Optical Cable**

- G: Outdoor Communication Optical Cable

- Y: Polyethylene (PE) Outer Sheath

- F: Non-metallic Reinforcing Member (FRP Fiberglass Rod)

- X: Central Loose Tube Type (Single Loose Tube)

- Y: Unarmored, No Metallic Armor Layer

 

 

## II. Internal Structure (From Inside to Outside)

1. **250μm Colored Fiber Optic**: A single tube can hold up to 2-12 cores (mainstream 2/4/6/8/12 cores), commonly using G.652D single-mode fiber.

2. **High-Modulus PBT Loose Tube**: The tube is filled with fiber optic water-blocking grease for buffering, waterproofing, and hydrolysis resistance.

3. **Longitudinal Water-Blocking Tape/Yarn**: Wraps the loose tube, achieving longitudinal waterproofing for the entire cable.

4. **Double Parallel FRP Non-Metallic Reinforcing Core**: One fiberglass rod on each side of the loose tube provides full tensile strength; **no metal throughout**.

5. **Black PE Outer Sheath**: UV resistant, high and low temperature resistant, abrasion resistant, suitable for outdoor duct installation.

 

## III. Core Product Features

1. **All-Metallic, Electromagnetic Interference Resistant, Lightning Protection** No steel wire or aluminum strip; ideal for pipelines near high-voltage cables, substations, and in mountainous areas prone to lightning strikes. It does not induce lightning current, requires no grounding, and eliminates the risk of cable breakage due to lightning strikes.

2. **Smaller Outer Diameter, Lighter Weight, Significant Advantages for Pipeline Installation** Smaller core count than GYTA and GYXTW, resulting in lower installation resistance. Suitable for low-voltage conduits, community low-voltage wells, municipal micro-pipes, and shared low-voltage conduits.

3. **Complete Water-Blocking Structure** Double waterproofing with internal grease and a water-blocking layer on the cable core, ensuring long-term stability in damp and water-accumulated underground environments.

4. **Wide Temperature Range Stability** Operating temperature: -40℃ to +70℃, suitable for use in both frigid northern regions and high-temperature southern regions.

5. **Mechanical Specifications (Standard 12-core specification)**

- Long-term allowable tensile force: 600N; Short-term tensile force: 1500N

- Long-term compressive force: 300N/100mm; Short-term compressive force: 1000N/100mm

- Static bending radius ≥ 15 times cable diameter, dynamic bending radius ≥ 30 times cable diameter

6. **Low cost, longer reel length** Simple structure, no metal armor, lower cost than armored optical cables; single reel can reach 2/3/4km, reducing joints.

 

 

## IV. Applicable Scenarios (Primarily for pipelines, but also suitable for overhead installation)

### 1. Pipeline Laying (Most Common Application)

- Municipal low-voltage power networks, underground PVC/HDPE pipelines in residential areas, low-voltage manholes

- Power trenches, high-voltage cables laid in the same trench (non-metallic, does not interfere with power, does not attract lightning)

- Underground micro-ducts from computer rooms to buildings, underground pipeline networks in industrial parks

### 2. Auxiliary Overhead Installation (Requires matching suspension lines, cannot be self-supporting)

Urban and rural low-voltage power pole installation, power pole installation of optical cables (dedicated to high-voltage areas)

 

### Unapplicable Scenarios

1. Direct Burial (No steel tape armor, pressure resistant, rodent-proof; direct burial must use GYFXY53 armored version)

2. Large-span overhead installation without suspension lines (No self-supporting structure; ADSS is suitable for long-span overhead installation)

## V. Comparison with Common Optical Cables

1. **GYFXY vs 1. **GYXTW**
Both are centrally bundled conduits; GYXTW is **reinforced with metal wire**, making it susceptible to lightning strikes and electromagnetic interference; GYFXY is double FRP non-metallic, offering lightning protection and interference resistance, making it the preferred choice for power/high-lightning-rate pipelines.

2. **GYFXY vs GYFTY**
GYFXY: **Single centrally bundled conduit**, with 2-12 cores, small outer diameter, and smooth pipe insertion;
GYFTY: **Layered loose-sleeve conduit**, capable of producing 24 or more cores, suitable for main trunk large-core pipelines.

3. **GYFXY vs GYTA**
GYTA has an aluminum metal sheath, posing a risk of electromagnetic induction; GYFXY is all-medium, and only GYFXY can be used in high-pressure trenches.

 

## VI. Selection Label Example

`GYFXY-12B1`

- GYFXY: Central tube type non-metallic unarmored optical cable

- 12: 12-core optical fiber

- B1: G.652D standard single-mode optical fiber (most commonly used in engineering)

 

## VII. Construction Precautions

1. The pulling force of the duct should not exceed 1500N for short periods to avoid FRP stretching and damage to the optical fiber;

2. Increase the bending radius at bends in the duct and manholes to avoid flattening;

3. For underground water accumulation and damp ducts, a high water-resistant reinforced GYFXY type can be selected;

4. For ducts with severe rodent infestation, it is recommended to replace with the armored non-metallic model GYFXY53.

 

Hot Tags: outdoor optical cable, China outdoor optical cable manufacturers, suppliers, factory, Duct Fiber Cable, duct optical fiber cable, Fiber Cable 24 Core, Kabel Duct Fiber Optic

Technical Characteristics

 

 

Fiber Count 2~24
Loose Diameters 2.0 ~2.6mm
Loose Material PBT (Polybutylene Terephthalate)
Strength Member Material Steel wire
Strength Member size 2 x 1.0 mm
Outer Jacket Material PE
Nominal Outer Dimensions 6.0~8.0 mm (±0.3)

Tension Strength

(Long-Term /Short-Term)

600N/1000N

Crush Resistance

(Long-Term /Short-Term)

300 N/100mm

1000 N/100mm

Minimum Bend Radius (Static / Dynamic) 10 x OD / 20 x OD

 

*All above the cable size can be customized.